2HP Copeland Low Temperature Refrigeration Condensing Unit

1. Cold room or cold storage Condensing unit with Copeland Scroll Compressor introduction and technical dataApplicationHotels, restaurants, medicines, agricultural, chemicals industries and other place when cold room is needed.Power Supply380V/3PH/50HZ,other power supply is optionalTemperature -5~15ºC/-5~ 5ºC/-15~

Featured Products

1. Cold room or cold storage Condensing unit with Copeland Scroll Compressor introduction and technical data
ApplicationHotels, restaurants, medicines, agricultural, chemicals industries
and other place when cold room is needed.
Power Supply380V/3PH/50HZ,other power supply is optional
Temperature -5~15ºC/-5~ 5ºC/-15~ -25ºC
Compressor BrandEmerson Copeland
Compressor TypeHermertic sroll
RefrigerantR22, R404A
 
**Low temperature unit     
Model ESSA~02NKSG03NKSG04NKSG05NKSG06NKSG
Room Tem range (ºC) -18ºC ~-20ºC
RefrigerantR22
Power supply380/400/415V/3Ph/50 HZ
Compressor modelZSI06KQZSI09KQZSI11KQZSI15KQZSI18KQ
CondenserFan qty11122
Fan voltage (V)220220220220220
Fan power(W)60606060*260*2
Cap.&input Te-20ºCCapacity(W)22502980387056306810
Input(W)16002020243033504200
 Te-25ºCCapacity(W)18202380316046005560
Input(W)15701980237032504110
 Te-30ºCCapacity(W)14801870252036704500
Input(W)15901960230031704020
 
Model ESSA~07NKSG08NKTG10NKTG13NKTG15NKTG
Room Tem range (ºC) -18ºC ~-20ºC -18ºC ~-30ºC
RefrigerantR22
Power supply380/400/415V/3Ph/50 HZ
Compressor modelZSI21KQZFI36KQEZFI50KQEZFI59KQEZFI68KQE
CondenserFan qty21112
Fan voltage (V)220220220220220
Fan power(W)60*2550550550460
Cap.&input Te-25ºCCapacity(W)62009050124001470017500
Input(W)449055907330893010600
 Te-30ºCCapacity(W)51207540103001225014550
Input(W)441053206940841010000
 Te-35ºCCapacity(W) 620084401010011950
Input(W) 5070659079809500
 Te-40ºCCapacity(W) 4910675080109540
Input(W) 4830633077209130
 
Model ESSA~02NKSGY03NKSGY04NKSGY05NKSGY06NKSGY
Room Tem range (ºC) -18ºC ~-20ºC
RefrigerantR404A
Power supply380/400/415V/3Ph/50 HZ
Compressor modelZSI06KQEZSI09KQEZSI11KQEZSI15KQEZSI18KQE
CondenserFan qty11122
Fan voltage (V)220220220220220
Fan power(W)140140140140*2140*2
Cap.&input Te-20ºCCapacity(W)23203270414059307220
Input(W)17602260264035804430
 Te-25ºCCapacity(W)18702640335048205900
Input(W)17302210258035204290
 Te-30ºCCapacity(W)15002070262037804770
Input(W)17002120245035004200
 
Model ESSA~07NKSGY08NKTGY10NKTGY13NKTGY15NKTGY
Room Tem range (ºC) -18ºC ~-20ºC -18ºC ~-30ºC
RefrigerantR404A
Power supply380/400/415V/3Ph/50 HZ
Compressor modelZSI21KQEZFI36KQEZFI50KQEZFI59KQEZFI68KQE
CondenserFan qty21112
Fan voltage (V)220220220220220
Fan power(W)140*2550550550380*2
Cap.&input Te-25ºCCapacity(W)659010350139501695019150
Input(W)474061608180994011550
 Te-30ºCCapacity(W)53508700115501405015850
Input(W)459058407800949011000
 Te-35ºCCapacity(W) 727095701165013100
Input(W) 54707410902010450
 Te-40ºCCapacity(W) 60508090983011100
Input(W) 5030705085609930
2HP Copeland Low Temperature Refrigeration Condensing Unit
2. Condensing unit Main Components
1. Compressor 2. Condenser 3. Oil heating 4. Suction& discharge valves 5. In/out pipe connection 6. H/L pressure gauge
7. Sight glasses 8. Solenoid valve 9. Diaphragm type pressure switch 10. Liquid filter 11. Liquid receiver 12. liquid injection valve


3. Cold room Condensing unit Features
1) Adopt world famous brand Copeland hermetic compressor, with high reliability, less vibration and low noise;
2) Adopt cabinet structure ,attractive appearance, compact structure, easy installation;
3) Condenser fan adopt high quality motor, high efficiency and low noise;
4) Adopt copper tube aluminum fin condenser, with more face area, high heat exchange efficiency and long service life.
5) Can meet high, medium and low temperature requires.


4. Condensing unit series:
2HP Copeland Low Temperature Refrigeration Condensing Unit
A: Wall/Roof mounted monoblock condensing unit
B:Box type Emerson Copeland compressor condensing unit
C: Box type Bitzer piston compressor condensing unit
D: Open type Bitzer piston compressor condensing unit
E:Open type Bitzer 2-stage compressor condensing unit
F: Bitzer Semi-hermetic piston compressor racks condensing unit
G: Bitzer Semi-hermetic screw compressor racks condensing unit
H: Hanbell Semi-hermetic screw compressor racks condensing unit


5.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com
Website 2: http://eurostarschiller.en.made-in-china.com
 
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com
 2HP Copeland Low Temperature Refrigeration Condensing Unit


2HP Copeland Low Temperature Refrigeration Condensing Unit
6.FAQ
Q: What information do you need to provide in order to get a quotation?
A: Generally, for condensing unit we need to know following items:
-Cooling Capacity,
-Required cold room temperature or evaporating temperature
-Water cooling system or air cooling system.
-Compressor brand
-Electrical power supply, such as 380V-3Phase-50HZ or 440V-3Phase-60HZ
-Refrigerant, such as R22 or R404a
-It is better there are local ambient temperature datas
If can not give full answers for above items, we can via another way, such as cold room dimension, application, etc

In order to providing a suitable solution and quotation for your application, please try as possible to let us know more your requirements and application, general enquiry requests:
1. What's the frozen products?
2. What's the temperature of cold room?
3. What's the temperature of frozen products?
4. What's the size of cold room?(L*M*H)
5. What's the power supply?
6. Which refrigerant do you need? R22 or R404A?
7. Which type unit you prefer? Scroll type, piston type or screw type?
8. Other requirements?


7. Installation instructions and project photo
1) The unit should be fixed at the site where the air is easy to flow, and far away from heat source;
2) In the storage building, the fixing hole for the unit should be made before the installation. The side of the hole should be made of wood, strong enough to support the unit.
3) Good quality wood should be embedded at the hole for bold fixing;
4) Fix the unit on the body of the storage room with bolts;
5) Seal the hole around the unit with sealing material;
6) Drainage pipe fixing: Fix the drainage pipe on the drainage mouth of the evaporator with pipe clam, ensure the direction is correct and the water could flow smoothly;
7) Electrical system fixing:
(1)Check the conformity of voltage the main power supply to that of name plate, the tolerance is ±10%;
(2)Air switch is required to ensure safety and flexibility.
(3)Grounding must be reliable;
8)Trial operation of the unit
(1)Verify that the electrical connection is correct before start the unit;
(2)Add water to the pan of evaporator until there can be see water comes out from the of drainage pipe at the condenser side;
(3)Close the air switch, one minute later, the indicator of the fan and refrigeration on the control panel will be on, means the operation is normal. Keep watch until operation is stable.
2HP Copeland Low Temperature Refrigeration Condensing Unit
8. Product package and deliver:
A:For cold room machine:Standard package f with plywood, the unit can be well protected, it is with pallet on the bottom for easy transportation., the unit can be well protected ,suitable for container shipment. 
B:For cold room panel:Plastic film for panel, Each panel is well wrapped with plastic film respectively, the corner is protected with brown paper. 

2HP Copeland Low Temperature Refrigeration Condensing Unit
9. Customers Visit
2HP Copeland Low Temperature Refrigeration Condensing Unit

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours